LIBRISTO
LIBROAMANTO
obrigatório
Faça parte de uma comunidade de amantes de livros de todo o mundo e tenha acesso a uma série de benefícios. Crie uma conta gratuitamente
0
Correio DHL 7.99 Correio DPD 4.49 Ponto DPD 3.99 Correio GLS 5.49 Correio MRW 5.49 Ponto GLS 4.49

Data Center Commissioning Checklist

A Practical Reference for Levels 1-5 Commissioning, Functional Performance Testing, and Integrated Systems Testing

Língua InglêsInglês
Livro Capa mole
Livro Data Center Commissioning Checklist Charles Nehme
Código Libristo: 53244208
Editoras Independently published, julho 2026
A working reference for commissioning teams responsible for delivering mission-critical facilities t... Descrição completa
? points 557 b Em breve Em breve Novo Novo
230.03
Reabastecimento esperado Lançamento 19. 07. 2026

Até 30 dias para devoluções

A working reference for commissioning teams responsible for delivering mission-critical facilities that meet the Owner's Project Requirements (OPR) on the first pass.

1.1 Purpose

Data center commissioning (Cx) is the structured, documented process that verifies mechanical, electrical, plumbing, fire/life safety, and controls systems are designed, installed, and operate in accordance with the Owner's Project Requirements (OPR) and the Basis of Design (BOD). Unlike commissioning in commercial office buildings, data center commissioning must validate not only steady-state operation but also every credible failure scenario a Tier III or Tier IV facility is expected to survive - utility loss, generator failure to start, UPS module failure, chiller trip, and N+1 or 2N redundancy loss.

This book provides a complete set of checklists, RAG-scored verification tables, weighted scoring matrices, and FMEA risk frameworks organized by commissioning level (Cx-1 through Cx-5), by building system, and by project phase - from design review through seasonal/deferred testing performed up to twelve months after substantial completion.

1.2 Who This Book Is For
  • Commissioning Authorities (CxA) and third-party commissioning agents
  • MEP design engineers performing design-phase Cx reviews
  • General contractors and MEP subcontractors coordinating start-up and testing
  • Data center owners, operators, and facility managers accepting the completed asset
  • Colocation and hyperscale program managers standardizing Cx across a portfolio
Charles Nehme Global MEP Consultant https://bit.ly/m/HVAC
Atriz & Poliglota
EWA KASP para
Reproduzir vídeo
Ewa Kasp
A Libristo tem a maior seleção de literatura estrangeira. É por isso que compro os meus livros aqui.

Sobre o livro

Nome completo Data Center Commissioning Checklist
Língua Inglês
Encadernação Livro - Capa mole
Data de emissão 2026
Número de páginas 58
EAN 9798187014040
Código Libristo 53244208
Peso 85
Dimensões 152 x 229 x 4
Ofereça este livro hoje
É fácil
1 Adicione ao carrinho e escolha Entregar como presente ao finalizar a compra 2 Receberá um vale 3 O livro chegará ao endereço do destinatário

Iniciar sessão

Inicie sessão na sua conta. Não tem uma conta Libristo? Crie uma agora!

 
obrigatório
obrigatório

Não tem uma conta? Descubra os benefícios de ter uma conta Libristo!

Com uma conta Libristo, terá tudo sob controlo.

Crie uma conta Libristo
Conselheiro de livros Libroamiko
Olá, sou o Libroamiko, posso ajudar?